1
Sensor IR 501 separate
Artkl. Nr: 0200207
For coating and glue line
Measuring distance: 5-10mm
40 milliseconds for error message
Circular measurement spot
Measuring distance/measuring spot 1:1
Operation: quantity measurement in %
Measuring distance: 5-10mm
40 milliseconds for error message
Circular measurement spot
Measuring distance/measuring spot 1:1
Operation: quantity measurement in %
2
Sensor IR 501S separate
Artkl. Nr: 0200287
Extra fast sensor for coating and glue line
3 milliseconds for error message
Measuring distance/measuring spot 1:1
Measuring distance: 5-10mm
Circular measurement spot
Operation: very fast error message for adhesive failure, adhesive dot counting, order quantity measurement in %
3 milliseconds for error message
Measuring distance/measuring spot 1:1
Measuring distance: 5-10mm
Circular measurement spot
Operation: very fast error message for adhesive failure, adhesive dot counting, order quantity measurement in %
3
Sensor IR 501SWL separate
Artkl. Nr: 0200288
Extra fast sensor, 3 milliseconds for error message
Rectangular spot size: 4x13mm
Measurement distance: 5-100mm
Operation: very fast error message for adhesive failure, adhesive dot counting, order quantity measurement in %
Rectangular spot size: 4x13mm
Measurement distance: 5-100mm
Operation: very fast error message for adhesive failure, adhesive dot counting, order quantity measurement in %
4
Sensor IR 502G separate
Artkl. Nr: 0200231
Sensor for monitoring trace of glue, specifically for
mounting on mobile devices (for example, robot arms)
60 milliseconds for error message
For monitoring adhesive directly under the applicator
Measurement distance: 50mm-150mm
Operation: spray adhesive, glue lines,
counting measurement in %
mounting on mobile devices (for example, robot arms)
60 milliseconds for error message
For monitoring adhesive directly under the applicator
Measurement distance: 50mm-150mm
Operation: spray adhesive, glue lines,
counting measurement in %
5
Sensor IR 501ACS separate
Artkl. Nr: 0200233
Data as Sensor IR501S, in addition to connecting for
air cooling and lens cleaning by compressed air.
Includes Air Filter F110
air cooling and lens cleaning by compressed air.
Includes Air Filter F110
6
Sensor IR 501AC separate
Artkl. Nr: 0200208
Data as Sensor IR501, in addition to connecting for
air cooling and lens cleaning by compressed air.
Includes Air Filter F110
air cooling and lens cleaning by compressed air.
Includes Air Filter F110
7
Sensor IR 502GAC separate
Artkl. Nr: 0200236
Data as Sensor IR502G, in addition to connecting for
air cooling and lens cleaning by compressed air.
Includes Air Filter F110
air cooling and lens cleaning by compressed air.
Includes Air Filter F110
8
Sensor IR 502GACV40 separate
Artkl. Nr: 0200241
Data as sensor IR 502G, in addition to connecting for
air cooling and lens cleaning by compressed air.
With 40mm additional tube against contamination and interference
air cooling and lens cleaning by compressed air.
With 40mm additional tube against contamination and interference
9
Sensor IR 502GS separate
Artkl. Nr: 0200232
Sensor data as sensor IR502G
Extra fast sensor: 5 milliseconds for error message
Extra fast sensor: 5 milliseconds for error message
10
Sensor IR 508G separate
Artkl. Nr: 0200209
Data as Sensor IR502G
Measuring distance/measuring spot: 50mm/8mm
Measuring distance/measuring spot: 50mm/8mm
11
Connection for air cooling and lens cleaning
Artkl. Nr: 0200216
Optional for the sensors IR 502G, IR 508G and IR 501
12
Side cable output for sensors IR502G and IR508G
Artkl. Nr: 0200237
13
Robot Cable
Artkl. Nr: 0200226
For the use on robots and drag chains
14
Steel flex jacket/Shielding line
Artkl. Nr: 0200238
15
Dust protector tube 40mm
Artkl. Nr: 0200211
Against contamination and interference, for
sensors IR502GAC und IR508GAC
sensors IR502GAC und IR508GAC
16
Sensor cable extension, per meter
Artkl. Nr: 0200225
Including plugs
17
Replacement Air Filter F110 for air cooling/lens cleaning
Artkl. Nr: 0200215
For all sensors with connection for air cooling and
lens cleaning by compressed air
lens cleaning by compressed air
18
Digitale Panelmeter DP1001
Version 230VAC
Artkl. Nr: 0200213
Version 24VDC
Artkl. Nr: 0200212
LED-Display with MIN/MAX limits selectable
Indication in %
Free selectable output: MIN/MAX relay contacts
Potential free, output: 0-10VDC
Input: 0-20mA or 4-20mA
Mounting dimensions: 96x48mm
Indication in %
Free selectable output: MIN/MAX relay contacts
Potential free, output: 0-10VDC
Input: 0-20mA or 4-20mA
Mounting dimensions: 96x48mm
19
Digitale % Display DP1002
Version 230VAC
Artkl. Nr: 0200228
Version 24VDC
Artkl. Nr: 0200229
LED-Display, indication in %
Free selectable output: 0-10VDC
Mounting dimensions: 96x48mm
Free selectable output: 0-10VDC
Mounting dimensions: 96x48mm
20
Base Unit 2000/GDC, 24VDC
Artkl. Nr: 2000240
24 VDC power supply, transmitter,
base unit for all sensors.
Measurement range 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10VDC
base unit for all sensors.
Measurement range 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10VDC
21
Base Unit 2000/G, 230VAC
Artkl. Nr: 2000230
230 VAC power supply, transmitter,
base unit for all sensors.
Measurement range 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10VDC
base unit for all sensors.
Measurement range 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10VDC
22
novasens 2000P/230 VAC
Artkl. Nr: 0200231
Replacement Circuit Board
Power supply: 230 Volt
Measurement range: 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10 VDC
Power supply: 230 Volt
Measurement range: 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10 VDC
23
novasens 2000P/24VDC
Artkl. Nr: 0200232
Replacement Circuit Board
Power supply: 24 Volt
Measurement range: 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10 VDC
Power supply: 24 Volt
Measurement range: 0-250%
Output switchable: 0-20mA, 4-20mA, 0-10 VDC
24
Optional Bargraphdisplay
Artkl. Nr: 0200555
Optional, built in to the housing
25
Adjustable switching alarm contact, potential free
Integrated in transmitter
Integrated in transmitter
Artkl. Nr: 0200113
Switches at glue gaps
26
Holdfunction 24VDC
Artkl. Nr: 0200220
Holdfunction/Triggerinput, 24VDC input, keeps the
measured value at adhesive gaps
measured value at adhesive gaps